Telescope |
DL-502 |
DL-503 |
Magnification |
32X |
28X |
Objective aperature |
45mm (1.78in.) |
36mm (1.42in.) |
Resolving power |
3″ |
3.5″ |
Field of view |
1°20” |
Minimum focus |
1.5m (5.0ft.) |
Image |
Erect |
Stadia ratio |
100 |
Compensator |
Type |
Pendulum compensator with magnetic damping system |
Working range |
±15’ |
Height mesurement |
Accuracy (standrd deviation for 1km double run levelimg) |
Electronic reading |
|
Invar staff |
0.6mm |
0.8mm |
Fiberglass staff |
1.0mm |
1.5mm |
Optical reading |
1.0mm |
2.0mm |
Measuring range |
1.6 to 100m (5.3 to 328ft.) |
Measuring time |
|
Fine |
3 sec. (single/continuous/average) |
Tracking |
1 sec. |
Least count |
0.0001/0.001m, 0.001/0.01ft., 1/8in. |
Minimum brightness condition |
20lx. at the staff surface |
Distance measurement (D=measuring distance) |
Accuracy |
|
D≦10m |
±10mm (±0.4in.) |
10m<D≦50m |
±0.1%×D |
50m<D |
±0.2%×D |
Least count |
0.01/0.1m, 0.1/1ft., 1in |
User interface |
Display |
128×32 dot matrix LCD with backlight |
Keyboard |
8 keys (7 on front panel, 1 on side panel) |
Cricular level sensitivity |
10’/2mm |
Mesurement program |
|
Single / Continuous / Average / Elevation / Height difference / Cut & Fill /
Stakeout distance |
Data storage |
Internal memory |
2,000 points |
JOB |
Max. 20 jobs |
Data output format |
CSV |
Interface |
|
RS-232C |
Environmental |
Water resistance |
IPX4 (IEC 60529:2001) |
Operating temperature |
-20°C to 50°C (-4°F to 122°F) |
Storage temperature |
-40°C to 70°C (-40°F to 158°F) |
Others |
|
BDC46B (Li-ion battery, 7.2V) |
Operating time |
Approx. 16 hours |
Weight (including battery) |
2.4kg (5.3 lb.) |
Size |
257(D)×158(W)×182(H)mm (10.1×6.2×7.2in.) |